Logo image
Experimental validation and clinical feasibility of 3D reconstruction of coronary artery bifurcation stents using intravascular ultrasound
Journal article   Open access

Experimental validation and clinical feasibility of 3D reconstruction of coronary artery bifurcation stents using intravascular ultrasound

Wei Wu, Akshat Banga, Usama M. Oguz, Shijia Zhao, Anjani Kumar Thota, Vinay Kumar Gadamidi, Vineeth S. Dasari, Saurabhi Samant, Yusuke Watanabe, Yoshinobu Murasato, …
PloS one, Vol.19(4), e0300098
2024
PMID: 38625996
Appears in  Miller School of Medicine - Latest Publications

Abstract

Humans Coronary Vessels/diagnostic imaging/surgery/anatomy & histology X-Ray Microtomography Imaging, Three-Dimensional Reproducibility of Results Stents Ultrasonography, Interventional Coronary Angiography/methods Coronary Artery Disease/diagnostic imaging/surgery Feasibility Studies
The structural morphology of coronary stents and the local hemodynamic environment following stent deployment in coronary arteries are crucial determinants of procedural success and subsequent clinical outcomes. High-resolution intracoronary imaging has the potential to facilitate geometrically accurate three-dimensional (3D) reconstruction of coronary stents. This work presents an innovative algorithm for the 3D reconstruction of coronary artery stents, leveraging intravascular ultrasound (IVUS) and angiography. The accuracy and reproducibility of our method were tested in stented patient-specific silicone models, with micro-computed tomography serving as a reference standard. We also evaluated the clinical feasibility and ability to perform computational fluid dynamics (CFD) studies in a clinically stented coronary bifurcation. Our experimental and clinical studies demonstrated that our proposed algorithm could reproduce the complex 3D stent configuration with a high degree of precision and reproducibility. Moreover, the algorithm was proved clinically feasible in cases with stents deployed in a diseased coronary artery bifurcation, enabling CFD studies to assess the hemodynamic environment. In combination with patient-specific CFD studies, our method can be applied to stenting optimization, training in stenting techniques, and advancements in stent research and development.
pdf
Experimental validation and clinical feasibility of 3D reconstruction of coronary artery bifurcation stents using intravascular ultrasound4.83 MBDownloadView
Open Access CC BY V4.0
url
https://doi.org/10.1371/journal.pone.0300098View
Published (Version of record) Open

Metrics

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
International collaboration
Citation topics
1 Clinical & Life Sciences
1.71 Cardiology - Circulation
1.71.242 Percutaneous Coronary Intervention
Web Of Science research areas
Cardiac & Cardiovascular Systems
ESI research areas
Clinical Medicine

Details

Logo image