Sign in
Pacemaker-Induced Hypotension
Journal article   Peer reviewed

Pacemaker-Induced Hypotension

Michael E Lewis, Ruey J Sung, Barry R Alter and Robert J Myerburg
Chest, Vol.79(3), pp.354-356
1981-03
PMID: 7471869

Abstract

We report a case of hypotension and decreased cardiac output resulting from artificial ventricular pacemaker rhythm. Hemodynamic deterioration was associated with loss of normal time relationships between atrial and ventricular contraction and paradoxical fall in systemic vascular resistance despite a low output state. The therapeutic implications of this unusual response are discussed.