Logo image
Stereotactic radiosurgery for multiple small brain metastases using gamma knife versus single-isocenter VMAT: Normal brain dose based on lesion number and size
Journal article   Open access   Peer reviewed

Stereotactic radiosurgery for multiple small brain metastases using gamma knife versus single-isocenter VMAT: Normal brain dose based on lesion number and size

Abram Abdou, Timoteo Almeida, Elizabeth Bossart, Irene Monterroso and Eric A Mellon
Journal of applied clinical medical physics, p.e70065
2025-03-19
PMID: 40108742

Abstract

radiosurgery SRS gamma knife linear accelerator Dosimetry
The study evaluates rapid linear accelerator (Linac) single isocenter stereotactic radiosurgery (SRS) with Hyperarc for large target numbers. We compared to Gamma Knife (GK), which suffers from long treatment times and investigated causes of differences. Linac SRS and GK treatment plans for patients receiving 18 Gy to the gross tumor volume (GTV) were evaluated for mean brain dose and volume of brain receiving 12 Gy or more (V12 Gy) as toxicity correlates. Further investigations included patient-based and simulations of 1-33 brain metastases to compare the ability of Linac SRS and GK to separate adjacent and distant lesions. For three patients (33, 33, and 18 metastases), GK reduced mean brain dose (2.89 Gy, 2.38 Gy, 2.79 Gy) compared to 2.5 mm microMLCs (4.36 Gy, 4.75 Gy, 4.26 Gy, p = 0.027) and 5 mm MLCs (4.71 Gy, 5.22 Gy, 4.60 Gy, p = 0.024). GK also improved V12 Gy (13.29 cc, 11.62 cc, 33.79 cc) compared to microMLC (25.31 cc, 30.91 cc, 54.71 cc, p = 0.019) and MLC (31.69 cc, 33.68 cc, 54.71 cc). This must be balanced with GK treatment times (5-11 h). GK achieved 50% prescription line separation at smaller distances (1.8-7.6 mm) than microMLC (7.7-10.2 mm) or MLC (8.8-12.2 mm) for 0.5-1.0 cm targets (4-8 mm collimator single shot). For 1.5 cm targets (16 mm shot) results were mixed (GK 5.4-17 mm, microMLC 9.5-11.2 mm, MLC 9.5-11.3 mm). A 7.7 cm simulation cube was then incrementally filled with 0.5 cm or 1.0 cm equidistant targets. GK plan mean brain dose increased 0.04 Gy/target (1.08 Gy mean/27 targets) compared to 0.14 Gy/target for microMLC (3.78 Gy mean/27 targets) for 0.5 cm targets, with differences diminishing for 1.0 cm targets (GK 0.15 Gy/target, microMLC 0.17 Gy/target). For numerous small metastases GK improves dosimetry but has exceedingly long treatment times. GK improves dose separation for adjacent lesions < 1.0 cm and conformity for small (∼0.5 cm) targets. GK and Linac differences are small for individual targets but compound over many targets. V12 Gy limits in the NCIC CE.7 trial protocol mandate dose modifications for Linac SRS but not GK.
pdf
Stereotactic radiosurgery for multiple small brain metastases using gamma knife versus single-isocenter VMAT: Normal brain dose based on lesion number and size2.72 MBDownloadView
Open Access CC BY V4.0
url
https://doi.org/10.1002/acm2.70065View
Published (Version of record) Open

Metrics

42 Record Views

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Citation topics
1 Clinical & Life Sciences
1.113 Brain Imaging
1.113.1726 Brain Metastases
Web Of Science research areas
Radiology, Nuclear Medicine & Medical Imaging
ESI research areas
Clinical Medicine