Abstract
Detection of neutrons through use of superheated emulsions has been known for about two decades. The minimum neutron energy (threshold) required to nucleate drops of a given liquid has a dependence on the temperature of the liquid. The basic principle of nucleation has been utilized to find the relationship between the operating temperature and threshold neutron energy for superheated emulsions made of R-114 liquid. The threshold energy thus determined for different temperatures has been compared with accurate experimental results obtained using monoenergetic neutron sources. The agreement is found to be satisfactory and confirms the applicability of the present simple method to other liquids.